SuperServer F619P2-RTN

  Products  Systems   FatTwin™   [ F619P2-RTN ]









Integrated Board
Super X11DPFR-SN




Views: | Angled (node) | Top (node) |

| Angled Front (system) | Rear (system) |



Key Features

8 Hot-plug System Nodes in 4U

Each node supports:




1. Dual Socket P (LGA 3647) support

    2nd Gen. Intel® Xeon® Scalable

    processors (Cascade Lake/Skylake)
2. 12 DIMMs; up to 3TB 3DS ECC

    DDR4-2933MHz RDIMM/LRDIMM,

    Supports Intel® Optane™ DCPMM††
3. Expansion slots: 1 PCI-E 3.0 x16 (LP)

    1 PCI-E 3.0 x16 (for SIOM )
4. 6 Hot-swap 2.5" SATA3 or 2 Hot-swap

    2.5" SATA3 + 4 NVMe U.2

    M.2 Interface: PCI-E 3.0 x4

    M.2 Form Factor: 2260, 2280, 22110

    M.2 Key: M-Key
5. SIOM Network card,

    1 dedicated IPMI LAN port
6. 1 VGA, 2 USB 3.0 ports
7. 3x 4cm 20k RPM middle fans
8. 2200W Redundant Power Supplies

    Titanium Level (96% Efficiency)


 Drivers & Utilities   BIOS   IPMI   Tested Memory  Tested M.2 List   NVMe Options   Manuals    OS Certification Matrix    Drive Options   Tested SIOM  Network Card (AOC) Matrix


Product SKUs
SYS-F619P2-RTN
  • SuperServer F619P2-RTN (Black)
 
Motherboard


Super X11DPFR-SN
 
Processor/Cache (per Node)
CPU
  • Dual Socket P (LGA 3647)
  • 2nd Gen. Intel® Xeon® Scalable Processors (Cascade Lake/Skylake),

    Dual UPI up to 10.4GT/s
  • Support CPU TDP 70-165W with IVR
Cores
  • Up to 28 Cores
Note BIOS version 3.0a or above is required to support 2nd Gen. Intel® Xeon® Scalable processors
 
System Memory (per Node)
Memory Capacity
  • 12 DIMM slots
  • Up to 3TB 3DS ECC DDR4-2933MHz RDIMM/LRDIMM
  • Supports Intel® Optane™ DCPMM††
Memory Type
  • 2933/2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM
Note 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro

†† Cascade Lake only. Contact your Supermicro sales rep for more info.
 
On-Board Devices
Chipset
  • Intel® C621 chipset
SATA
  • SATA3 (6Gbps); RAID 0, 1, 5, 10
Network Controllers
  • Flexible networking via SIOM
IPMI
  • Support for Intelligent Platform Management Interface v.2.0
  • IPMI 2.0 with virtual media over LAN and KVM-over-LAN support
Graphics
  • ASPEED AST2500 BMC
 
Input / Output (per node)
SATA
  • 14 SATA3 (6Gbps) ports
NVMe
  • 4 NVMe U.2 option
LAN
  • SIOM flexible Network card
  • 1 RJ45 Dedicated IPMI LAN port
USB
  • 2 USB 3.0 ports (rear)
VGA
  • 1 VGA port
 
System BIOS
BIOS Type
  • 128Mb SPI Flash EEPROM with AMI BIOS
 
Management
Software
Power Configurations
  • ACPI Power Management
 
PC Health Monitoring
CPU
  • Monitors for CPU Cores, Chipset Voltages, Memory.
  • 4+1 Phase-switching voltage regulator
FAN
  • Fans with tachometer monitoring
  • Status monitor for speed control
  • Pulse Width Modulated (PWM) fan connectors
Temperature
  • Monitoring for CPU and chassis environment
  • Thermal Control for fan connectors
Chassis
Form Factor
  • 4U Rackmount
Model
  • CSE-F418BC2-R2K20BP
 
Dimensions and Weight
Width
  • 17.63" (448mm)
Height
  • 6.96" (177mm)
Depth
  • 29" (737mm)
Package
  • 28.3" (W) x 15.0" (H) x 42.4" (D)
Weight
  • Net Weight: 150 lbs (68.04 kg)
  • Gross Weight: 200 lbs (90.71 kg)
Available Colors
  • Black
 
Front Panel
Buttons
  • Power On/Off button
  • UID button
LEDs
  • Power status LED
  • Hard drive activity LED
  • Network activity LEDs
  • Information LED (UID, Fan failure, Overheat)
 
Expansion Slots (per node)
PCI-Express
  • 1 PCI-E 3.0 x16 (Low-profile)
  • 1 PCI-E 3.0 x16 (SIOM)
 
Drive Bays (per node)
Hot-swap
  • 6 Hot-swap 2.5" SATA3 or 2 Hot-swap 2.5" SATA3 + 4 NVMe U.2
M.2
  • M.2 Interface: PCI-E 3.0 x4
  • M.2 Form Factor: 2260, 2280, 22110
  • M.2 Key: M-Key
 
Backplane
1 SAS/SATA backplane
 
System Cooling (per node)
Fans
  • 3x 4cm 20k RPM middle fans
 
Power Supply
2200W Redundant Power Supplies with PMBus
Total Output Power and Input
  • 1200W with Input 100-127Vac
  • 1800W with Input 200-220Vac
  • 1980W with Input 220-230Vac
  • 2090W with Input 230-240Vac
  • 2200W with Input 220-240Vac (for UL/cUL use only)
  • 2090W with Input 230-240Vdc (for CCC only)
AC Input Frequency
  • 50-60Hz
Dimension

(W x H x L)
  • 76 x 40 x 336 mm
+12V
  • Max: 100A / Min: 0A (100-127Vac)
  • Max: 150A / Min: 0A (200-220Vac)
  • Max: 165A / Min: 0A (220-230Vac)
  • Max: 174.17A / Min: 0A (230-240Vac)
  • Max: 183.3A / Min: 0A (220-240Vac)
5VSB
  • Max: 1A / Min: 0A
Output Type
  • Backplanes (gold finger)
Certification Titanium Level96%  Titanium Level

  [ Test Report ]
 
Operating Environment
RoHS
  • RoHS Compliant
Environmental Spec.
  • Operating Temperature:

       10°C ~ 35°C (50°F ~ 95°F)
  • Non-operating Temperature:

       -40°C to 60°C (-40°F to 140°F)
  • Operating Relative Humidity:

       8% to 90% (non-condensing)
  • Non-operating Relative Humidity:

       5% to 95% (non-condensing)


See Parts List



Parts List - (Items Included)
 

Part Number

Qty

Description

Motherboard / Chassis MBD-X11DPFR-SN

CSE-F418BC2-R2K20BP
8

1
Super X11DPFR-SN Motherboard

4U Chassis
Backplane BPN-ADP-X11DPFR 8 Power distribution board for X11DPFR-S(N)
Backplane BPN-SAS3-F418-B6N4 8 6-Port Hybrid Backplane Supports 2x2.5” SAS3/SATA3 HDD/SDD and 4x2.5” SAS3/SATA3/NVMe Storage Devices for FatTwin Platform
Cable 1 CBL-0486L 16 2x2 to 2x2 15cm power cable HF. 18AWG
Cable 2 CBL-OTHR-0022L 8 20 to 20 pin cable for BPN-ADP-F418LS,7.5cm, 28AWG,RoHS/REACH,PBF
Cable 3 CBL-PWCD-0578 4 PWCD,US,IEC60320 C14 TO C13,3FT,14AWG
Cable 4 CBL-SAST-0532 16 MINI SAS HD,12G,INT,50CM,30AWG
Cable 5 CBL-SAST-1002-1 32 OcuLink v 1.0,INT,PCIe NVMe SSD, 13CM,34AWG
Riser Card RSC-RR1U-E16 8 RSC-RR1U-E16 with PIC-E x16 output
Heatsink / Retention SNK-P0067PS 8 1U Passive CPU Heat Sink for X11 Purley Platform Equipped with a Narrow Retention Mechanism
Heatsink / Retention SNK-P0067PSM 8 1U Passive CPU Heat Sink with a 26-mm Wide Middle Air Channel for X11 Purley Platform Equipped with a Narrow Retention Mechanism
Power Supply PWS-2K20A-1R 4 1U 2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm




Optional Parts List
  Part Number Qty Description
SIOM Cards for FatTwin Various 1/node See FatTwin SIOM Compatibility Matrix
Network Card(s) AOC-SGP-i2/4

AOC-STGN-i1S/i2S

AOC-STGF-i2S

AOC-STG-i4S

AOC-STG-b4S

AOC-STG-i2T

AOC-STGS-i1/2T

AOC-STG-i4T

AOC-STG-i2

AOC-S25G-m2S

AOC-S40G-i2Q

More
- Standard LP, 2/4x GbE RJ45, PCI-E x4, Intel i350

Standard LP, 1/2x 10GbE SFP+, PCI-E x8, Intel 82599EN

Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel XL710-BM2

Standard LP, 4x 10GbE SFP+, PCI-E x8, Intel XL710

Standard LP, 4x 10GbE SFP+, PCI-E x8, Broadcom BCM57840S

Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540

Standard LP, 1/2x 10GbE RJ45, PCI-E x8, Intel X550

Standard LP, 4x 10GbE RJ45, PCI-E x8, Intel XL710

Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB

Standard LP, 2x 25GbE SFP28, Mellanox ConnectX-4 LX EN

Standard LP 2-port 40GbE controller, Intel Fortville XL710

AOC Compatibility Matrix
TPM security module AOM-TPM-9670H-S-O 1/node SPI capable vertical TPM 2.0 provisioned for client,RoHS
Intel VROC RAID Key AOC-VROCINTMOD

AOC-VROCSTNMOD

AOC-VROCPREMOD
1/node

1/node

1/node
Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only)

Intel VROC Standard, RAID 0, 1, 10

Intel VROC Premium, RAID 0, 1, 5, 10
Add-on card for Additional M.2 NVMe AOC-SLG3-2M2 1/node Low Profile PCI-E x8 add-on card supports 2 PCI-E 3.0 x4 M-Key M.2 NVMe Modules
Alternative Rack Rail Kit MCP-290-00077-0N 1/system SLIDING RAILS, BLADE SERVER for round-hole rack, M5 thread
2 NVMe Drive Kit for CPU1 AOC-SLG3-2E4T-P

CBL-CDAT-0674

CBL-SAST-0818
1/node

1/node

2/node
2 Port NVMe PCIE X8 Retimer

4 Pin to 4 Pin I2C cable, 30cm, 26AWG, 4 wires, pinout 1-1, for vpp header

OCuLink v. 1.0,INT,PCIe NVMe SSD, 55CM,34AWG
4 NVMe Drive Kit for CPU1 AOC-SLG3-4E4T-P

CBL-CDAT-0674

CBL-SAST-0818
1/node

1/node

4/node
4 Port NVMe PCIE X16 Retimer

4 Pin to 4 Pin I2C cable, 30cm, 26AWG, 4 wires, pinout 1-1, for vpp header

OCuLink v. 1.0,INT,PCIe NVMe SSD, 55CM,34AWG
Global Services & Support OS4HR3/2/1

OSNBD3/2/1
-

-
3/2/1-year onsite 24x7x4 service

3/2/1-year onsite NBD service
Software SFT-OOB-LIC 1 OOB Management Package (per node license)
Software SFT-DCMS-Single 1 DataCenter Management Package (per node license)
Hide Parts List



Information in this document is subject to change without notice.

Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.